LEDs

On the MWR-KIT, three LEDs are available:

B

Blue LED: Radio (radio activity)

G1

Green LED: Controller (Power Focus 6000 connection)

G2

Green LED: System (job active)

LEDs behavior:

  • Blue LED (B): switched on when an exchange of information between MWR-KIT and MWR using radio frequencies is active.

  • Green LED (G1): switched on when MWR-KIT has an active connection to Power Focus 6000 and a MWR is linked correctly.

  • Green LED (G2): switched on when the tightening program or sequence is running.

     

Startup

Status

B

G1

G2

Boot loader

Off

On for 2 s

Off

Normal operations

Status

B

G1

G2

Radio activity ok

Blinking

--

--

One or many active DASP connections to Power Focus 6000 (with linked MWR)

--

On

--

All selected tools successfully configured

--

--

On

Device on – no DASP connection

Off

Blinking

Off

Errors

Status

B

G1

G2

System error (assert/crash)

Off

Off

Off

System in configuration mode

--

Off

Blinking

No tool selected (linked)

Off

--

Off

For one of linked tools one of the following conditions verifies:

  • Wrench is offline

  • Wrench is out of range

  • Wrench is not ready to be activated

  • Wrench is not configured in a virtual station (only linked to MWR-KIT)

--

--

Blinking

SD card access error (R/W fail)

On

--

--