Tightening Tracker

The Tightening Tracker module is a system that monitors the tightening process and communication with the controllers. If it detects errors or abnormalities it will send messages in the message bus. Enabling the Tightening Tracker can help troubleshoot the tightening process.

Enabling the Tightening Tracker
  1. In Diagnosis mode, on the Modules page, mark the row for Tightening Tracker.

  2. Select the Start module button.

Error list

Message

Code

Warning/Error

Related to tightening result

Assistant message mapper

User feedback/action

Start already received for positioningID: <positioningID>

ID001

tightening_error

No

Process is stopped/option to continue

The process needs to be stopped, ask the user to check controller configurations for self-lock.

PositioningId not found in last tightening: <positioningId>

ID002

tightening_fatal

Yes

Process is stopped/option to continue

This could never happen, Controller is sending "empty" or a wrong positioning ID.

Stop already received for positioningID: <positioningId>

ID003

tightening_error

No

Process is stopped/option to continue

The process needs to be stopped, ask the user to check controller configurations for self-lock.

Fast result already received for positioningID: <positioningId>

ID004

tightening_error

Yes

Process is stopped/option to continue

The process needs to be stopped, ask the user to check controller configurations for self-lock.

Result already received for positioningID: <positioningId>

ID005

tightening_error

Yes

Process is stopped/option to continue

The process needs to be stopped, ask the user to check controller configurations for self-lock.

Tool is released while setting PositioningID: <positioningId>

ID006

tightening_error

No

Process is stopped/option to continue

It could be due to something wrong in the ILG process.

PositioningID doesn't match to any entered volume!

ID007

tightening_error

No

Process is stopped/option to continue

This could be due to timing (communication between the controller and ILG).

Invalid acknowledge of set positioningId!

ID008

tightening_fatal

No

Process is stopped/option to continue

System error

PositioningID set while tool is released

ID009

tightening_error

No

Process is stopped/option to continue

System error

Start received with empty positioningID

ID010

tightening_error

No

Process is stopped/option to continue

Controller self-lock not enabled.

Stop received with empty positioningID

ID011

tightening_error

No

Process is stopped/option to continue

Controller self-lock not enabled.

Fast result received with empty positioningId!

ID012

tightening_error

Yes

Process is stopped/option to continue

System error

Result received with empty positioningId!

ID013

tightening_error

Yes

Process is stopped/option to continue

System error

Re-hit detected

PRO001

tightening_warning

Yes

User notification

Check configuration for automatic lock after every tightening.

Possible re-hit detected

PRO002

tightening_warning

Yes

User notification

Check configuration for automatic lock after every tightening.

Tightening result does not match fast result

RES001

tightening_error

Yes

Process is stopped/option to continue

This should never happen, but if it does, there is something wrong in the controller. Indicator that Tightening Queue is not in expected order.

Timestamp in tightening result doesn't match. It is before the volume was entered!

RES002

tightening_error

Yes

Process is stopped/option to continue

HMI: Check synchronization of both systems (controller, system where ILG is running).

Pset of position does not match to the one in the result

RES003

tightening_error

Yes

Process is stopped/option to continue

Check configuration for automatic lock after every tightening.

Tightening stopped received before started

SEQ001

tightening_error

Yes

Process is stopped/option to continue

System error

Tightening fast result received before started

SEQ002

tightening_error

Yes

Process is stopped/option to continue

Indicator that Tightening Queue is not in expected order.

Tightening result received before started

SEQ003

tightening_error

Yes

Process is stopped/option to continue

System error

Invalid order: Tightening and loosening are not in sequence

SEQ004

tightening_error

Yes

Process is stopped/option to continue

System error

tc_fast_result detected without corresponding start!

SEQ005

tightening_error

Yes

Process is stopped/option to continue

System error

tc_result detected without corresponding start!!

SEQ006

tightening_error

Yes

Process is stopped/option to continue

System error

Tightening was started while tool was locking!

SEQ007

tightening_error

No

Process is stopped/option to continue

Tightening started after ILG tried to lock the tool but before controller acknowledged the lock - this will lead to dropped result (SEQ010/011) if tightening is finished.

Tightening was started while tool was releasing!

SEQ008

tighening_warning

No

Process is stopped/option to continue

Tightening started after ILG released the tool but before controller acknowledged release - indication of controller slowdowns but not an direct issue.

Tightening was started while tool was locked!

SEQ009

tightening_error

No

Process is stopped/option to continue

Controller reported that the tool is locked and running at the same time: Can happen in some cases if controller is heavily loaded/and or tool trigger spamming.

OK result dropped!

SEQ010

tightening_error

Yes

Process is stopped/option to continue

Unstable positioning: When the tool is physically "on" a position, it should stay in volume even if the tool move around slightly. Too short pset run time: Ex rehit type tightenings/second passes. Controller delays can in this case cause ILG to ignore results if the tightening was reported when the tool already moved out of volume.

NOK result dropped!

SEQ011

tightening_error

Yes

Process is stopped/option to continue

Unstable positioning: When the tool is physically "on" a position it should stay in volume even if the tool move around slightly. Too short pset run time: Ex rehit type tightenings/second passes. Controller delays can in this case cause ILG to ignore results if the tightening was reported when the tool already moved out of volume.

Tightening started in multiple enabled volumes

VOL001

tightening_error

No

Process is stopped/option to continue

Check overlapping volumes.

Tightening started in multiple volumes

VOL002

tightening_warning

No

User notification

Check if overlapping volumes are intended (staged tightening in forced order).

Tightening started outside of volumes

VOL003

tightening_error

No

Process is stopped/option to continue

Indicator that controller / ILG connection has timing issues. Ask the user to contact AC service technician. (Reduce workload on controller, update controller, ...).

Tightening stopped in multiple enabled volumes

VOL004

tightening_error

No

Process is stopped/option to continue

Check overlapping volumes.

Tightening stopped in multiple volumes

VOL005

tightening_warning

No

User notification

Check if overlapping volumes are intended (staged tightening in forced order).

Tightening stopped outside of volumes

VOL006

tightening_warning

No

User notification

Check if the tool has been moved out of volume during tightening. Check if volume covers the whole tightening movement. Check geometry setup. See also VOL003.

Tightening stopped in a different volume

VOL007

tightening_error

No

Process is stopped/option to continue

Indicator that controller / ILG connection has timing issues. Ask the user to contact AC service technician. (Reduce workload on controller, update controller, ...) Check if the volume covers the whole tightening movement.

Volume left during tightening

VOL008

tightening_warning

No

User notification

Check if the tool has been moved out of volume during tightening. Check if the volume covers the whole tightening movement. Check geometry setup.

Multiple volumes of different workplaces entered during tightening

VOL009

tightening_warning

No

User notification

Check overlapping volumes.