SSD - Stick Slip Detection

Tools

ES

STR

SL

ST

SR

QST

IXB

This step monitor detects and reports stick slip effects during a step. The detection is done by counting the number of times the torque falls below the Trigger Level. If the number of times is larger than Maximum Number of Oscillations then the stick slip error is reported. The monitor operates in two different modes, Dynamic or Fixed. The difference between the modes is the way that the Trigger level is calculated.

Dynamic Torque: Trigger Level is dynamically calculated as Peak Torque Percentage of the current max torque, which has been achieved so far during the monitoring. The monitoring is started as soon as the torque passes the Trigger Torque.

Fixed Torque: Trigger Level is the fixed Trigger Torque specified by the user. In this mode the percentage is not needed.

If the torque never reaches the Trigger Torque then the monitoring is not started, this will result in status NOK.

Parameter

Description

Type

Specifies what type of Stick slip detection that will be done in the monitor Stick Slip detection. Default: Dynamic torque.

Peak Torque Percentage

Default: 80%, Must be >=10 and < 100.

Trigger Torque

Default: 5, Must be >= 0 and < Tool max torque.

Maximum Number of Oscillations

Default: 5, Must be >= 3 and <20.