Fieldbus Sizes

Item

DeviceNet

Ethernet/IP

Profinet I/O

Profibus DP-V1a

CC Link

CC link IE

a only for Profibus DP-V1:Transfer speed for acyclic data is ~1 kB/s, depending on how often you trigger tightenings this will be the bottleneck for how much acyclic data you can transfer. For example, if you perform a tightening every 3 seconds you should not try to transfer more than 3 kB/tightening

Max. cyclic data (Read + Write)

512

512

512

128(368)

N/A

512

Min. cyclic data (Read + Write)

0

0

0

1

N/A

0

Max. cyclic data (Write)

256

256

256

128(244)

N/A

256

Min. cyclic data (Write)

0

0

0

0

N/A

0

Max. cyclic data (Read)

256

256

256

128(244)

N/A

256

Min. cyclic data (Read)

0

0

0

0

N/A

0

Max. acyclic data (Read + Write)

65535

65535

65535

65535

N/A

65535

Min. acyclic data (Read + Write)

0

0

0

0

N/A

0

Max. acyclic data (Write)

65535

65535

65535

65535

N/A

65535

Min. acyclic data (Write)

0

0

0

0

N/A

0

Max. acyclic data (Read)

65535

65535

65535

65535

N/A

65535

Min. acyclic data (Read)

0

0

0

0

N/A

0

 

CC Link Version 1

Occupied stations

Bit points (bits)

Word points (words)

Total (Bit + Word, in bytes)

1

32

4

12

2

64

8

24

3

96

12

36

4

128

16

48

CC link version 2

Occupied stations

1 Extension cycle

2 Extension cycles

4 Extension cycles

8 Extension cycles

Points

Total

Points

Total

Points

Total

Points

Points

1

32 bits

12 bytes

32 bits

20 bytes

64 bits

40 bytes

128 bits

80 bytes

4 words

8 words

16 words

32 words

2

64 bits

24 bytes

96 bits

44 bytes

192 bits

88 bytes

384 bits

176 bytes

8 words

16 words

32 words

64 words

3

96 bits

36 bytes

160 bits

68 bytes

320 bits

136 bytes

640 bits

272 bytes

12 words

24 words

48 words

96 words

4

128 bits

48 bytes

224 bits

92 bytes

448 bits

184 bytes

896 bits

368 bytes

16 words

32 words

64 words

128 words