Step Sync I/O Signals

The StepSync system supports the same I/O signals listed in the tables below. These can be mapped in fieldbus configuration and accessory configuration. Some are also available through Open Protocol.

StepSync Input Signals

Code

Input Signal

Type

Description

10010

Tightening start (continuous)

State

 

10011

Loosening start (continuous)

State

Start the sync mode with index 99

10016

Select input bit 0

State

For selection of sync mode

10017

Select input bit 1

State

For selection of sync mode

10018

Select input bit 2

State

For selection of sync mode

10019

Select input bit 3

State

For selection of sync mode

10020

Select input

State

For selection of sync mode

10024

Tightening start (pulse)

Event

10028

Start drive

State

Active signal starts the tool (default operation mode is tightening). As soon as signal goes inactive the tool must be stopped. Used in combination with 10029 (Select loosening).

10029

Select loosening

State

Selects loosening as default operation mode and used in combination with 10028 (Start drive).

10030

Tightening/Loosening stop (pulse)

Event

10045

External identifier

State

i.e. VIN number

10049

Disable Fieldbus

State

10054

Channel command

State

Array with command for each channel

10055

Enable operation

State

Must be set to be able to run tightenings

10056

Reset cycle status

State

Clear all the tightening-related output signals

10057

Disable test bolt

State

10062

Reset System Error

State

10064

From PLC

State

10065

To PLC

State

10066

Select input bit 4

State

For selection of sync mode

10067

Select input bit 5

State

For selection of sync mode

10068

Select input bit 6

State

For selection of sync mode

10069

Select input bit 7

State

For selection of sync mode

10070

Select input bit 8

State

For selection of sync mode

10071

Select input bit 9

State

For selection of sync mode

10071

Loosening start (pulse)

State

Start the sync mode with index 99

10072

Loosening start (pulse)

Event

Loosening sync mode is started when this signal goes high.

Runs until the loosening is finished, even if the Loosening Start (pulse) signal goes low.

10113

Start drive (pulse)

Event

StepSync Output Signals

Code

Output Signal

Type

Description

42

IO on

State

 

72

Selected Mode Id

State

75

Cycle OK

State

Total status of the last tightening was OK

76

Cycle NOK

State

Total status of the last tightening was NOK

77

Cycle complete

State

78

Cycle running

State

80

Channel tightening status

State

Array with tightening status for each channel

81

Channel hardware status

State

Array with hardware status for each channel

82

Cycle ready to start

State

83

No System Error

State

85

Software Release Version

State

86

Software Major Version

State

87

Software Minor Version

State

88

Configuration Version

State

91

Test bolt activated

State

96

Fieldbus Disconnected

State

102

No System Warning

State

20036

Emergency stopped

State