ISO 6789:2003 parameters
The ISO 6789:2003 test is available for tool types Click wrench and Peak.
General category
Name: type the name of the inspection.
Barcode identifier: it identifies the inspection. If left blank, the identifier corresponds to the inspection name.
Measurement device type: STbench is the only measurement device type available for this test strategy.
Measurement device S/N: type the serial number of the measuring device connected to the device.
Tightening direction: from the drop down list select the tightening direction. The available options are:
Clockwise
Counterclockwise
Disable manual insert: select the check box to set the value measured by the wrench automatically as the target torque of the phase (defined by the standard ISO 6789:2003) of the maximum of the torque range of the tool.
This parameter is shown only for Peak tools.
Phase 1 category
Target torque: unavailable value. The target torque is equal to a percentage value of the maximum capacity of the tool. This parameter is defined by the ISO 6789:2003 standard.
Torque tolerance: unavailable value. The torque tolerance is equal to percentage value defined by the ISO 6789:2003 standard.
Number of samples: unavailable value. The number of results to do it is equal to 5. This value is defined by the ISO 6789:2003 standard.
STbench channel: select the STbench channel to use to do the test. The available options are:
Manual selection.
Number of the STbench channel (from 1 to 8).
Transducer S/N: type the serial number of the transducer linked to the measuring device connected to the device.
Each wrench type defined by the ISO 6789:2003 standard has a different number of test points and different target torque. All the test points have the same configuration of the Phase 1 described above.
Refer to the ISO 6789:2003 standard for more information.