Multistep Program Tool Compatibility Table

The availability of steps, monitors and restrictions depends on the license installed on the controller.

The table below shows which steps, monitors and restrictions are available for the various tools.

Supported Tools

ES

ST

STR

SR

SL (Low Voltage)

BCV-RE/BCP-RE

MWR

STB

QST

STW

External Tool

PF8-Handheld

X

X

X

X

X

X

X

X

X

X

X

PF8-StepSync

-

X

X

X

X

-

-

-

X

-

-

Step Type

ES

ST

STR

SR

SL (Low Voltage)

BCV-RE/BCP-RE

MWR

STB

QST

STW

External Tool

Tighten to Angle

X

X

X

X

X

-

-

X

X

-

-

Tighten to Torque

X

X

X

X

X

-

-

X

X

-

-

Tighten to Trigger Release

X

X

X

X

X

-

-

X*

-

-

-

Tighten to Torque plus Angle

X

X

X

X

X

-

-

X

X

-

-

Tighten to Torque and Angle

X

X

X

X

X

-

-

X

X

-

-

Tighten to DynaTork

X

X

X

X

X

-

-

X

X

-

-

Wait

X

X

X

X

X

-

-

X

X

-

-

Socket Release

X

X

X

X

X

-

-

X

X

-

-

Run until Digital Input

X

X

X

X

X

-

-

-

X

-

-

Tighten to Torque or Angle

X

X

X

X

X

-

-

X

X

-

-

Loosen to Angle

X

X

X

X

X

-

-

X

X

-

-

Loosen to Torque

X

X

X

X

X

-

-

X

X

-

-

Loosen to Trigger Release

X

X

X

X

X

-

-

X*

-

-

-

Thread Cutting to Torque

X

X

X

X

X

-

-

X

X

-

-

Synchronization Point

-

X***

X***

X***

X***

-

-

-

X***

-

-

Engage

X

X

X

X

X

-

-

-

X

-

-

Rundown

X

X

X

X

X

-

-

-

X

-

-

Tighten to Yield

X

X

X

X

X

-

-

-

X

-

-

Tighten to Yield M2

-

-

-

-

-

-

-

-

X

-

-

External Result

X

X

X

X

X

X

-

X

X**

-

X

Clutch

-

-

-

-

-

X

-

-

-

-

-

Clutch Loosening

-

-

-

-

-

X

-

-

-

-

-

Mechatronic Wrench (MWR)

-

-

-

-

-

-

X

-

-

-

-

Torque Calibration

-

-

-

-

-

-

-

-

-

-

-

Wrench Production

-

-

-

-

-

-

-

-

-

X

-

Wrench Quality

-

-

-

-

-

-

-

-

-

X

-

Tensor Pulse

-

-

X

X

-

-

-

-

-

-

-

Monitors
(Evaluated at End of Step)

ES

ST

STR

SR

SL (Low voltage)

BCV-RE/BCP-RE

MWR

STB

QST

STW

External Tool

Time

X

X

X

X

X

-

-

X

X

-

-

Angle

X

X

X

X

X

-

X

X

X

X

-

Peak Torque

X

X

X

X

X

-

X

X

X

X

-

Shut-Off Torque

X

X

X

X

X

-

-

X

X

-

-

Torque Rate and Deviation

X

X

X

X

X

-

-

-

X

-

-

Post Thread Cut Angle

X

X

X

X

X

-

-

X

X

-

-

Post Thread Cut Peak Torque

X

X

X

X

X

-

-

X

X

-

-

Torque in Angle Window

X

X

X

X

X

-

-

X

X

-

-

Post View Torque High

X

X

X

X

X

-

-

X

X

-

-

Post View Torque Low

X

X

X

X

X

-

-

X

X

-

-

Angle from Yield

X

X

X

X

X

-

-

-

X

-

-

Stick Slip detection

X

X

X

X

X

-

-

-

X

-

-

Prevailing Torque

X

X

X

X

X

-

-

X

X

-

-

Shut-Off Current

X

X

X

X

X

-

-

X

X

-

-

Click

-

-

-

-

-

-

X

-

-

-

-

Torque Calibration

-

-

-

-

-

-

-

-

-

-

-

Loosening Detection

-

-

-

-

-

-

-

-

-

X

-

Restrictions (Immediate Stop)

ES

ST

STR

SR

SL (Low voltage)

BCV-RE/BCP-RE

MWR

STB

QST

STW

External Tool

Maximum Torque

X

X

X

X

X

-

-

X

X

-

-

Maximum Angle

X

X

X

X

X

-

-

X

X

-

-

Maximum Time

X

X

X

X

X

-

-

X

X

-

-

Cross Thread

X

X

X

X

X

-

-

X

X

-

-

Torque Gradient

X

X

X

X

X

-

-

-

X

-

-

Rescinding Torque - Torque control process

X

X

X

X

X

-

-

X

X

-

-

Rescinding Torque - Angle control process

X

X

X

X

X

-

-

-

X

-

-

Torque Vs Current Deviation

X

X

X

X

X

-

-

-

X

-

-

Torque in Angle Window

X

X

X

X

X

-

-

X

X

-

-

Rehit

X

X

X

X

X

-

-

X

X

-

-

Pulse Count High

-

-

X

X

-

-

-

-

-

-

-

Program Monitor Type
(Evaluate at end of program)

ES

ST

STR

SR

SL (Low voltage)

BCV-RE/BCP-RE

MWR

STB

QST

STW

External Tool

Program Monitor Angle

X

X

X

X

X

-

-

X

X

-

-

Program Restriction Type
(Immediate Stop)

ES

ST

STR

SR

SL (Low voltage)

BCV-RE/BCP-RE

MWR

STB

QST

STW

External Tool

Program Restriction Torque High

X

X

X

X

X

-

X

X

X

X

-

Program Restriction Time High

X

X

X

X

X

-

X

X

X

-

-

* The STB tool only allows loosen to trigger/tighten to trigger release step in a multistep loosening/tightening program.

** External result is not supported in a PF8 StepSync system.

*** Only supported by PF8-StepSync systems.