Fieldbus parameters for Profibus

The table below only lists specific parameters for Profibus. For the general parameters, see Fieldbus Parameters General.

Field

Description

Default value

Sync on task selected

If enabled the fieldbus frame shall be Re-synced at task changes

Extended mode

Chooses between the backward compatible152 bytes data mode and the 368 bytes data mode:

  • On: 368 bytes data mode.

  • Off: 152 bytes data mode.

Fieldbus node address

 

 

Max ADI size

Choose between the different application data instance sizes to be set as a maximum.

Data consistency is only guaranteed for data mapped over one single ADI, that is, if the data to be sent is larger, or broken over two ADIs, data consistency cannot be guaranteed. Setting a maximum ADI size, which is equal to the sent data type size and mapped correctly to the total frame size will guarantee data consistency.

The maximum data size to use for sending cyclic data, which must match the data size used in the Fieldbus master. Max size ADIs will be used until less than that size remains to map. For example, If Max ADI size is set as 8 bytes, then that will be used for mapping until less than 8 bytes remain, then 4, 2, 1 bytes will be used to transfer the rest of the data.

To controller

Total receive Process Data Frame. The frame size is a combination of all the virtual station receive frames. The size is expressed in number of bytes.

From controller

Total transmit Process Data Frame. The frame size is a combination of all the virtual station transmit frames. The size is expressed in number of bytes.