Detailed NOK reason
|  
 NOK reason  |  
 Description  | 
|---|---|
| 
 Rundown time high  | 
 The measured time from the activation time until rundown complete is higher than the time maximum limit.  | 
|  
 Rundown time low  |  
 The measured time from the activation time until rundown complete is lower than the time minimum limit.  | 
|  
 Final tightening time high  |  
 The measured time from the activation time until the tightening target reached is higher than the time maximum limit  | 
|  
 Final time tightening low  |  
 The measured time from the activation time until the tightening target reached is lower than the time minimum limit  |