Active Identifier String 3 - 190
Signal corresponding to the third configured string in Source batch-string. 
Active Identifier String 3 signal is sent once a scanning sequence is done and a sequence has been selected, thus the identifier parts are active. 
The strings is filtered with saved position. 
Only sent when running Source batch string.
Name in SoftPLC: ACTIVE_ID_STRING_3
Converter  | Signal Type  | Value Type  | Size Min [bit]  | Size Max [bit]  | 
|---|---|---|---|---|
Standard  | State  | String  | 8  | 800  | 
IdentifierU32Hnw  | State  | String  | 8  | 800  | 
IdentifierU32  | State  | String  | 8  | 800  | 
Devices
Fieldbus: TRUE
Indicator Box: FALSE
Internal I/O: FALSE
Operator Panel: FALSE
Tool Functions: FALSE
ST Selector: FALSE
Stacklight: FALSE
TLS Tag: FALSE
I/O Expander: FALSE
To avoid duplicating signals, it is possible to define Value Converters.
Converters are used to support more than one representation of the same signal (for example Angle/Torque Status can both be represented bitwise or as a status character).