Handling Tightening Sync Mode Configuration
Double-click on a tightening Sync Mode to configure that Sync Mode.
Properties
Parameter  | Description  | 
|---|---|
Name  | A user defined name for the mode.  | 
Description  | Description of the mode.  | 
Referencing Loosening Sync Mode
A tightening Sync Mode can be linked to a loosening Sync Mode. Referencing a loosening sync mode is located in the Properties menu of a tightening Sync Mode
Select the relevant loosening Sync Mode from the Loosening Sync mode drop-down.

The number of bolt configurations and the channel numbers used in the bolt configurations of the tightening Sync Mode should be the same as the loosening Sync Mode selected and a warning is displayed if they differ.
Reject Management
Action if failure  | Description  | 
End all  | 
  | 
Continue OK  | 
  | 
Bolt configuration
To add bolt configurations, click ADD or ADD MANY. You can have maximum of 64 bolt configurations.
Parameter  | Description  | 
|---|---|
Check box  | Used when, for example, deleting a channel.  | 
Channel  | Number of the channel, also named drive index.  | 
Tightening program  | Select tightening program defined in the menu Tightening Program.  | 
Bolt  | The actual fastener that is tightened when a tightening is made. This number will be used as the address when collecting data for the specific bolt, for example, in the fieldbus signal Bolt tightening status.  | 
Bolt name (optional)  | Name of the bolt.  |