Tool Configuration - Vibrator
Tools equipped with a vibrator can be configured to emit vibrations for different signals.
The vibrator is configured by assigning a vibration pattern to a signal selected from a list. A vibration signal can have a priority between 1 and 10, where 1 is the highest priority and 10 the lowest. By default a signal and vibration have the priority 5.
A vibration signal runs until termination unless it is interrupted by a signal with higher priority.
- Select a controller in the Plant structure workspace  . .
- Select the Configurations icon  in the top-side menu bar in the workspace area. in the top-side menu bar in the workspace area.- The workspace area displays a list of configurations. 
- Double-click on a configuration row that has Tool configuration in the Type column. - Alternatively, select Add to create a new tool configuration. 
- Double-click on a configuration to open the selected configuration menu. - The Vibrator menu shows if an IXB tool is connected. 
- Set the parameters as applicable: - Parameter - Description - Signal - Select a signal to assign a vibration pattern. - Priority - 10 different priority levels are available for the vibrations where 1 is the highest priority level. Default priority level is 5. - On Time - Time (in ms) that the tool emits vibrations. - Off Time - Time (in ms) that the vibrator is quiet. - Repeats - Number of times the vibrator repeats the on/off sequence.