Actions act as outputs from a rule. To receive an output from the rule, the action needs to be configured to a Signal and a Virtual Station. A maximum of 10 actions can be configured per rule. In case of multiple triggers, an action or multiple actions are executed when the trigger condition is met.
Setting | Description |
---|---|
Name | Enter a name for the action with a maximum of 32 ASCII characters. |
Signal | Select from the list of available Boolean Input/Output state or event signals in the controller. The signal is then published to the virtual station selected in the action. |
Virtual station | Select from a list of available virtual stations. |
Output | Use the toggle to select the output value True to be published when the trigger is triggered. The default value is False. |
Selected Input/Output Boolean state / Event signal as Signal in Action | The output value is published to the signal configured in the action. The action can be reset using the Cease. Available cease configuration options:Rule State, Time, To Next Tightening, and Defined Signal. The cease configuration is set to Rule State by default. |