Signal Actions

A Signal Action sends signals to the system based on a configured Virtual Station. A valid Signal Action includes a Virtual Station, a Boolean input/output state or event signal, and a state to send when triggered. You must also configure a Cease setting to define how the Signal Action stops. By default, it follows the state of the rule and the trigger condition.

Setting

Description

Name

Enter a name for the action with a maximum of 32 ASCII characters.

Signal

Select from the list of available Boolean Input/Output state or event signals in the controller. The signal is then published to the virtual station selected in the action.

Virtual station

Select from a list of available virtual stations.

Output

Use the toggle to select the output value True to be published when the trigger is triggered. The default value is False.

Selected Input/Output Boolean state / Event signal as Signal in Action

The output value is published to the signal configured in the action. The action can be reset using Cease. Available cease configuration options:Rule State, Time, To Next Tightening, and Defined Signal. The Cease configuration is set to Rule State by default.