Cease
Cease configuration is enabled when an Input/Output Event Boolean signal is selected for a trigger, and is always enabled for an action.
Setting  | Applies to  | Description  | 
|---|---|---|
Time  | Trigger Action  | The user can set the time (in seconds), with a minimum value greater than 0 and a maximum value less than or equal to 60.  | 
Trigger  | The trigger ceases after the specified time.  | |
Action  | The action ceases after the specified time.  | |
To Next Tightening  | Trigger Action  | The trigger or action is reset when the Clear Results - 39 signal is published in the virtual station of the rule.  | 
Trigger  | The trigger ceases after the signal is received.  | |
Action  | The action ceases after the signal is received.  | |
Defined Signal  | Trigger Action  | The trigger or action is reset when a user defined signal is received. 
 Depending on the selected reset signal, the available scenarios are: 
  | 
Trigger  | The trigger ceases after the reset signal is received.  | |
Action  | The action ceases after the reset signal is received.  | |
Rule State  | Action  | When the trigger condition is met, the action publishes the user configured output value.  |