Enabling correct Projection Orientation
Place the three uniquely identified tags in an L-shape.

Make sure that all the three tags are clearly visible by the ILS sensor.
In Setup Mode, on the IL SpotPoint page, in the Workspace tab, select the START button.
Confirm that all three tags are detected under Tag\Sensor.

If any tag is missing: adjust the position of the tag while keeping the L-shape of the three tags, until the tag is detected.
Select TEACH ALL SYSTEM DATUM.
A Teach all System Datum window appears.
In the Origin Id box enter the first tag ID, in the Point on X-axis Id enter the second tag ID and in Point on XY-pane id enter the third tag ID.

E.g. the first tag ID is 23 then Origin Id is 23, the Point on X-axis Id is 24 and the Point on XY-pane id is 25.
Select SAVE to save the configuration.
Select STOP to stop the system.
Calibrate the IPG according the the standard calibration procedure.

For information about the calibration procedure, refer to the IPG Page Configuration chapter.
In Configuration Mode, on the Tightening Positions page, select a row for the workspace.
Select the RETEACH button and follow the instruction for reteach. For more information, refer to the Reteach Operations chapter, or the Reteach Relative Operations chapter if a dynamic tag is used.
Confirm that the orientation of the projections is correct.