ILG Status Bar
The status bar is located at the bottom of the screen. The status bar shows information for a number of items that are described below. If an error appears for an item on the status bar, its background color turns red.
Item | Status Descriptions | Example Values | Error Descriptions | |
|---|---|---|---|---|
a In ILG, a target is a collection of tags. | ||||
Version | The ILG version that is used | 2.6.0 | ||
Workflow | The workflow state. | wait_stop_tool | ||
Tool | The name of the tool model that is used | IxB | ||
Part Targeta Id | The part target ID is displayed if used in a workpiece. | 2 | Target not visible. This could indicate that an ILS is used when ILS is not available. | |
Dir | The direction of the tool | counterclockwise, clockwise | ||
Pset | The ID of the tightening program that is selected on a controller. The value inside of parentheses is confirmed by the controller. The value outside of the parentheses is set by ILG. | 10 (1) | ||
Lock type | The lock type that is used | AOP, ILG, DIG, SOFTPLC, NONE | ||
State | The tool state The states are listed and explained in the States table. | EMPTY_BATT, TIGHT_DISABLED | ||
Volumes | The volume in which the tool operates. | Intersecting, Volumes (2) | ||
Coordinates | Values for the x, y, and z coordinates. | 30 mm, 120 mm, 50 mm |
| |
States
This is a list of states and a description of each state.
State | Description |
|---|---|
CTRL_STARTED | The controller started an event. |
LOW_BATT | The battery level is low. |
EMPTY_BATT | The battery is empty. |
BAD_BATT | The battery status is bad. Consider replacing the battery. |
DIG_LOCK | The tool is locked by the DIG lock. |
AOP_LOCK | The tool is locked by the AOP lock. |
FIELDBUS_LOCK | The tool is locked by the Fieldbus lock. |
SELECTOR_LOCK | The tool is locked by the Selector lock. |
SOFT_PLC_LOCK | The tool is locked by the SoftPLC lock. |
LOOSE_DISABLED | Loosening is locked by the self-lock. |
TIGHT_DISABLED | Tightening is locked by the self-lock . |
NO_LOOSENING | A loosening program is not configured in the tightening program. |
NO_PSET | A tightening program is not selected on the controller. |
BATCH_LOCK | The tool is locked by the batch lock. |
STOPPED | The tightening is stopped by an external source. |
BAD_PSET | An invalid tightening program is used for this tool. Select another tightening program. |
WRONG_SOCKET | The wrong type of socket is used. Select a correct type of socket to use. Alternatively, no tightening program is selected. |
TOOL_LOCKED | The tool is locked. |
ILM_LOCK | The tool is locked by the ILM lock. |
ILG_LOCK | The tool is locked by the ILG lock. |
OPCUA_LOCK | The tool is locked by the OPC UA lock. |