Reading the Trace Category

Position

Name

Definition

1

Upper limit

Upper limit value for the function under control.

2

Result

Test result value. If the Double result function is enabled, both the residual point and the peak point are shown in the plot.

3

Lower limit

Lower limit value for the function under control.

4

Inspection name

Name of the selected inspection.

5

Full-screen button

Button for opening a full-screen view of the plot. In full-screen mode, it is possible to select and zoom in on a section of the curve.

6

Plot type button

Button for selecting the plot type to be displayed. Default plot is Torque over Angle.

7

Next button

Button for moving to the trace of the next result inside the inspection.

8

Previous button

Button for moving to the trace of the previous result inside the inspection.

9

Test number

Number of the test inside the inspection.

10

Batch count

Number of times the test has been run inside the inspection.