Air quality
For optimum performance and maximum machine life we recommend the use of compressed air with a maximum dew point of +10°C. We also recommend the installation of an Atlas Copco refrigeration-type air dryer.
Use a separate air filter of type Atlas Copco FIL. This filter removes solid particles larger than 15 microns and also removes more than 90 % of liquid water. The filter must be installed as close as possible to the machine/equipment and prior to any other air preparation unit such as REG or DIM (please see Air Line Accessories in our main catalogue). Blow out the hose before connecting.
Models which need air lubrication:
The compressed air must contain a small quantity of oil.
We strongly recommend that you install an Atlas Copco oil lubricator (DIM). This should be set according to air consumption by the air line tool according to the following formula:L = Air consumption (litre/s)
D = Number of drops per min (1 drop = 15 mm3)
L* 0.2 = D
this applies to the use of long work cycle air line tools. A single point lubricator type Atlas Copco Dosol can also be used for tools with short running cycles.
Information about Dosol settings may be found under Air Line Accessories in our main catalogue.
Lubrication-free models:
In the case of lubrication-free tools it is up to the customer to decide on the peripheral equipment to be used. However, it is no disadvantage if the compressed air contains a small quantity of oil e.g. supplied from a fog lubricator (DIM) or Dosol system.
Note – This does not apply to turbine tools, which should be kept oil free.