Joint parameters
General category
Name (*): type the Joint name. The maximum number of characters permitted is equal to 50.
Description: type the Joint description. The maximum number of characters permitted is equal to 50.
Identifier: type the Joint identifier. The maximum number of characters permitted is equal to 50.
Tightening direction: select the tightening direction. The available items are Clockwise and Counterclockwise.
Notes: type the optional Joint notes.
Torque category
Unit of measurement: select the unit of measurement to use.
Final angle monitoring torque: type the final angle monitoring torque value.
The final angle monitoring torque must be equal or higher than the Minimum torque.
By default the value is the 50% of the Target torque.
Control mode: select how to define the torque limits. The options are: Min/Max and Target/tolerance.
Minimum torque (*): type the minimum value of the torque. This parameter is available if Control mode is set to Min/Max.
Target torque (*): type the value of the target torque.
Maximum torque (*): type the maximum value of the torque. This parameter is available if Control mode is set to Min/Max.
Torque tolerance (*): type the value of the tolerance of the torque. This parameter is available if Control mode is set to Target/Tolerance.
Angle category
Control mode: select how to define the angle limits. The options are: Min/Max and Target/tolerance.
Minimum angle (*): type the minimum value of the angle. This parameter is available if Control mode is set to Min/Max.
Target angle (*): type the value of target angle.
Maximum angle (*): type the maximum value of the angle. This parameter is available if Control mode is set to Min/Max..
Angle tolerance (*): type the value of the tolerance of the angle. This parameter is available if Control mode is set to Target/Tolerance.
Items marked with an asterisk (*) are required.