Working with the Tools Tab

The Tools workspace displays a list of tools connected to the controller. The displayed menus differ between the controllers for fixtured tools and controllers for handheld tools and provide detailed information about connected tools.

In the menu Settings, tool alarms can be set. Trigger points for these alarms are taken from the Tools menu.

To view the tool menus:

  1. Select a controller in the Plant structure workspace .

  2. Go to Tools section.

    A list of tools connected to the controller is displayed.

    Column

    Description

    Tool type

    Describes the type of the tool.

    Model

    A detailed model number of the tool.

    Serial number

    The serial number of the tool.

    MAC address

    The MAC address is only visible if the tool has got a MAC address.

    Software version

    The software version of the tool.

    Max torque

    The maximum torque value the tool can produce.

    Max torque with TurboTight

    The maximum torque value the tool can produce when using the TurboTight strategy.

    Applicable only to certain tools.

    Max torque with TensorPulse

    The maximum torque value the tool can produce when using the TensorPulse strategy.

    Applicable only to certain tools.

    Max speed

    The maximum rotation speed of the tool.

    Next calibration

    Date for the next calibration of the tool.

    Virtual station

    The name of the virtual station to which the tool is connected.

    Channel

    The channel number of the tool.

  3. Double-click on one of the tools in the table for more detailed information.

How to connect a tool or how to make a wireless pairing is described in the controller manual.

General information

The menu is valid for a controller that supports fixtured tools or handheld tools.

Information

Description

Model

Tool model denomination.

Serial number

Tool serial number.

MAC address

The MAC address is only visible if the tools have a MAC address.

Product number

The same as ordering number.

Software version

Tool software version number.

The general tool information is provided by the tool itself to the controller and to ToolsTalk 2.

Limits

The menu is valid for a controller that supports fixtured tools or handheld tools.

Information

Description

Max torque

The maximum torque the tool can use for a tightening.

Max speed

The maximum rotation speed of the tool.

Min torque

The minimum torque the tool can use for a tightening.

Gear ratio

The ratio of the angular velocity of the input gear to the angular velocity of the output gear.

The tool limit information is provided by the tool itself to the controller and to ToolsTalk 2.

Connection

Connection to the controller and to which virtual station it is assigned.

Service settings

Calibration

The menu is used to control how well a tool corresponds to a reference transducer and how to adjust differences.

The calibration value is stored in the tool memory and is used to adjust the torque value given by the tool’s torque transducer so that the correct torque value is displayed on the controller. The controller displays last calibration date.

Tool calibration is carried out at the controller and uses a torque reference transducer. This process is described in the Power Focus 6000 manual.

Store the new calibration value in the tool memory by entering the calculated value, and then click Set.

Parameter

Description

Last calibrated

Date for last calibration.

Calibration value

Enter the measured and calculated value into the parameter entry box.

Next calibration

Due date for next calibration.

Set

Stores the entered values.

Maintenance

The tool stores a service interval number and counts how many tightenings that can be performed before the next tool maintenance or service should be performed.

Parameter

Description

Last service

Date and time when last service was performed. The last service date is set at the repair workshop. The Last service date is set to current date and time when the Reset button is pressed.

Total tightenings at service

The Total tightenings at service is the total number of tightenings performed by the tool since it was used for the first time. This value is updated at service, and will remain the same until the next service.

Remaining tightenings

Total number of tightenings left until the service interval is reached.

Service interval

Number of tightenings to be performed before the next service. Can be set in multiples of 10 000.

Set

The command stores the value entered in the Service interval parameter entry field and adjusts the value to a multiple of 10 000.

Reset service counter/data

The Reset command resets the counter and sets the Last service date to the current date.

Transducer information

Only available for FlexSystem and Synchronized tightening with QST tools.

A tool can have one main and one secondary torque transducers and one main and one secondary angle transducers. For each transducer (torque or angle), the information shows here.

Angle transducer

Information

Description

Enabled

Indicates if the transducer is enabled.

Gear ratio

The gear ratio between the transducer and the out-going shaft of the tool.

Wind-up

The wind-up compensation factor for the angle transducer.

Torque transducer

Information

Description

Enabled

Indicates if the transducer is enabled.

Serial Number

Serial number of the transducer as a string.

Article Number

Article number of the transducer as a string.

Calibration Value

Calibration value for the transducer expressed in Nm.

Health

The menu provides data from environmental monitors. The equipment measures parameters regularly and stores them.

Parameter

Description

Value

Refresh

Command button: read tool value.

History

Command button:
History window opens to display latest temperature readings.

Tool motor temperature

Latest temperature recording expressed in month/day/year hours:minutes:seconds.

Degree C or F

Tool electronics temperature

Latest temperature recording expressed in month/day/year hours:minutes:seconds.

Degree C or F

Zero offset and shunt limits

Only available for FlexSystem.

A tool can have one main and one secondary torque transducers. For each torque transducer, the limits show here.

Information

Description

Shunt Limit

Maximum allowed measured shunt calibration value in %.

Shunt Drift Limit

Maximum allowed change in measured shunt calibration value in %.

Zero Offset Limit

Maximum allowed Zero offset compensation in %.

Zero Offset Drift Limit

Maximum allowed change in the zero offset compensation in %.