Fieldbus parameters for CC Link
The table below only lists specific parameters for CC Link. For the general parameters, see Fieldbus Parameters General.
Field  | Description  | Default value  | 
|---|---|---|
Baud rate  | Speed of the communication link. Select speed from the drop-down menu. 156 kbps; 625 kbps; 2500 kbps; 5 Mbps; 10 Mbps.  | 156 kbps  | 
Fieldbus node address  | A unique address for each separate unit within the network  | |
Version  | Version 1: By default, the module automatically calculates the required number of Occupied Stations based on the mapped Process Data. Version 2: By implementing the Network Settings in the CC-Link, it is possible to customize the implementation for CC-Link Version 2 and use larger data sizes through Extension Cycles.  | |
Occupied stations  | A parameter setting which is dependent on which Version has been chosen. This is used in combination with the Extension Cycles parameter.  | |
Extension cycles  | Parameter setting used for sending larger data sizes, used in combination with the Version and Occupied Station parameters.  | |
To controller  | Total receive Process Data Frame. The frame size is a combination of all the virtual station receive frames. The size is expressed in number of bytes.  | |
From controller  | Total transmit Process Data Frame. The frame size is a combination of all the virtual station transmit frames. The size is expressed in number of bytes.  |