Fieldbus parameters for CC Link
The table below only lists specific parameters for CC Link. For the general parameters, see Fieldbus Parameters General.
Field | Description | Default value |
---|---|---|
Baud rate | Speed of the communication link. Select speed from the drop-down menu. 156 kbps; 625 kbps; 2500 kbps; 5 Mbps; 10 Mbps. | 156 kbps |
Fieldbus node address | A unique address for each separate unit within the network | |
Version | Version 1: By default, the module automatically calculates the required number of Occupied Stations based on the mapped Process Data. Version 2: By implementing the Network Settings in the CC-Link, it is possible to customize the implementation for CC-Link Version 2 and use larger data sizes through Extension Cycles. | |
Occupied stations | A parameter setting which is dependent on which Version has been chosen. This is used in combination with the Extension Cycles parameter. | |
Extension cycles | Parameter setting used for sending larger data sizes, used in combination with the Version and Occupied Station parameters. | |
To controller | Total receive Process Data Frame. The frame size is a combination of all the virtual station receive frames. The size is expressed in number of bytes. | |
From controller | Total transmit Process Data Frame. The frame size is a combination of all the virtual station transmit frames. The size is expressed in number of bytes. |