Handling Tightening Sync Mode Configuration
Double-click on a tightening Sync Mode to configure that Sync Mode.
Properties
Parameter | Description |
---|---|
Name | A user defined name for the mode. |
Description | Description of the mode. |
Referencing Loosening Sync Mode
A tightening Sync Mode can be linked to a loosening Sync Mode. Referencing a loosening sync mode is located in the Properties menu of a tightening Sync Mode
Select the relevant loosening Sync Mode from the Loosening Sync mode drop-down.
The number of bolt configurations and the channel numbers used in the bolt configurations of the tightening Sync Mode should be the same as the loosening Sync Mode selected and a warning is displayed if they differ.
Reject Management
Action if failure | Description |
End all |
|
Continue OK |
|
Bolt configuration
To add bolt configurations, click ADD or ADD MANY. You can have maximum of 64 bolt configurations.
Parameter | Description |
---|---|
Check box | Used when, for example, deleting a channel. |
Channel | Number of the channel, also named drive index. |
Tightening program | Select tightening program defined in the menu Tightening Program. |
Bolt | The actual fastener that is tightened when a tightening is made. This number will be used as the address when collecting data for the specific bolt, for example, in the fieldbus signal Bolt tightening status. |
Bolt name (optional) | Name of the bolt. |