Handling Tightening Sync Mode Configuration

  • Double-click on a tightening Sync Mode to configure that Sync Mode.

Properties

Parameter

Description

Name

A user defined name for the mode.

Description

Description of the mode.

Referencing Loosening Sync Mode

A tightening Sync Mode can be linked to a loosening Sync Mode. Referencing a loosening sync mode is located in the Properties menu of a tightening Sync Mode

  1. Select the relevant loosening Sync Mode from the Loosening Sync mode drop-down.

    The number of bolt configurations and the channel numbers used in the bolt configurations of the tightening Sync Mode should be the same as the loosening Sync Mode selected and a warning is displayed if they differ.

Reject Management

Action if failure

Description

End all

  • All channels will end the tightening and report status NOK.

  • The tightening that did not have an error itself will report additional info Terminated by other bolt.

Continue OK

  • The failing channels will end the tightening with status NOK.

  • The remaining channels will continue with the rest of the tightening program.

Bolt configuration

To add bolt configurations, click ADD or ADD MANY. You can have maximum of 64 bolt configurations.

Parameter

Description

Check box

Used when, for example, deleting a channel.

Channel

Number of the channel, also named drive index.

Tightening program

Select tightening program defined in the menu Tightening Program.

Bolt

The actual fastener that is tightened when a tightening is made. This number will be used as the address when collecting data for the specific bolt, for example, in the fieldbus signal Bolt tightening status.

Bolt name (optional)

Name of the bolt.