Status

When the Sync Reference controller is connected and online and the hardware layout configuration is in sync with the controller, ToolsTalk 2 will start to receive notifications about changes in the hardware deployment status. Once notified, ToolsTalk 2 will ask the controller for the Hardware measurement data.

To see detailed deployment status and measurement data:

  1. Select the product in the configuration area. Multiple products can be selected by pressing Ctrl and then selecting.

  2. Click on the Status bar to expand the window.

Tool configurations: Choose a configuration from the drop-down menu.

Inhibit mode: If there is something wrong with the channel (Controller or tool), inhibit mode can be set to continue using your hardware:

  • False: Channel is running OK.

  • Report OK: Channel is disabled and reports OK in result.

  • Report NOK: Channel is disabled and reports NOK in result.

  • Report No Result: Channel is disabled and does not show up in the result.

State: Text and symbols display the present state

Health: Text and symbols display the present health

Tips:

  • The height of panel can be increased by dragging the top border.

  • To get the latest measurement data, select Refresh.

  • The details displaying the Health status can be expanded to view more information. Select Show only NOK to only view the data with NOK results.