StepSync Results

The tightening results are displayed in a condensed list that can be individually or collectively chosen for further analysis.

For each controller, a maximum of 1024 latest received results can be stored in the ToolsTalk database. When the controller is offline, the results occurring during this time will not be transferred to ToolsTalk when the controller returns online.

Select Show only NOK reslults at the bottom of each page to only view the results with NOK status.

On the top level the result for a synchronized tightening with several channels contain the following information:

Tightening result

GUI part

Description

Red bar

The leftmost position in the Live results table may contain a red bar icon. This is shown together with erroneous tightenings for quick identification of errors. This corresponds to NOK.

Holding pin

Select the holding pin icon to pin the result to the pinned tab.

Trace icon

Select the trace icon to view a graphical view of the results in the Trace workspace.

Save icon

This command creates a .csv-file with the result data. A dialog window is opened as to save the file in a desired location.

Shunt calibration

Shown if shunt calibration is displayed.

Overall Status

Total status of the tightening, OK or NOK.

Type

Virtual station name

Name of the virtual station.

Sync Mode Index and name

Index and name of the sync mode used in the tightening.

Time Stamp

Time stamp for the tightening, that is, time and date.

Channel result

For each channel an overall result is reported with the following content:

GUI part

Description

Trace icon

Select the trace icon to view a graphical view of the results in the Trace workspace.

Save icon

This command creates a .csv-file with the result data. A dialog window is opened as to save the file in a desired location.

Bolt name

The number and name of the bolt. Set in Sync Mode > “Name of the sync mode” > Bolt configuration > Bolt and Bolt name.

Status

Total status of the tightening, OK or NOK.

Status info

If available

Multistep name

The name of the tightening program. Set in Tightening and Multistep Program > “Name of the tightening program” > Basic settings > Name .

Channel

The channel number.

Final Angle

The actual measured angle of the last tightening step It is the Step Monitor Peak Angle located in the last tightening step that reports this parameter.

Target Angle

Target Angle

Start Final Angle

The Start Final Angle will display the torque value from where the Final Angle was initiated.

Final Torque

Final Torque for the tightening. It is the Step Monitor Peak Torque located in the last tightening step that reports this Parameter.

Elapsed time

Time from tightening start to end.

Shunt calibration

Select this icon to display the shunt calibration data.

Step results

Each step in the multistep tightening program reports data. Most of this data is coming from the monitors and restrictions that are active during the step, so the data is only reported if a monitor or restriction of the correct type is configured.

The same step may be executed more than once if repairs are made.

Result Parameter

Description

Step number

The number of the step.

Status

Status of the step, OK or NOK.

Step type

Step type in the multistep program.

Path

Indicates where in the program the step is located, that is, if it is in the tightening path, a repair, or a termination path.

Peak Torque

Measured final torque including the torque induced during the internal break. Typically the peak torque is higher than the shut-off torque.

Elapsed time

Time from tightening start to end.

Angle

Displays the angle

Click Torque

Displays the Click Torque

Click Angle

Displays the Click Angle

Result Reporter

The list shows the values from the result reporters. If there is a result reporter defined for a program monitor/restriction, the value from that monitor/restriction is reported. If there is no result reporter defined for a program monitor/restriction, the value from the latest executed step in main path with a reporter is reported.

Trace

On a result select the Trace icon if it is active . The result graph is then displayed. It is possible to compare several traces simultaneously by selecting each trace in the list.

The Trace workspace shows detailed graphical information of one or several tightening results.

In the workspace, use the mouse wheel to zoom in or zoom out. Alternatively you can select an area to zoom in on. Double-click the trace area to go back.

Examples:

Select an area to zoom in:

To move the trace, press the wheel button of the mouse:

In the trace graph, delta information based on the selected axis types can be displayed. Right-click the two points you want to compare to show the delta between them. Drag the point to modify the target.

Drag the delta to move it or press Delete to delete it.

Trace settings/preferences

Description

Show limits

Check this box to if one curve is shown, limit values can be shown if they are used in the tightening program.

Show Min/Max

Show minimum or maximum measured value.

Peak Sync

Different curves may look the same, but are placed differently in the graph.

This option creates an overlay of the curves and synchronizes their peak values.

Manual Sync

|X-Axis|

Show the absolute value for X-axis.

Y1

Choose the information to be shown in the Y1-axis:

  • Torque

  • Angle

  • Speed

  • Current

  • Gradient

Y2

Choose the information to be shown in the Y2-axis:

  • None

  • Torque

  • Angle

  • Speed

  • Current

  • Gradient

Y3

Choose the information to be shown in the Y3-axis:

  • None

  • Torque

  • Angle

  • Speed

  • Current

  • Gradient

X

Choose which information to be shown X-axis:

  • Time

  • Angle

Remove all Δ

Remove all the deltas.

Save...

This command creates a picture of the graphical area. A dialog window is opened as to save the file in a desired location. The file name is by default export.png.

Remove all

This button clears the trace plot area.

The traces are still in the results and can be accessed again in "live results" workspace.

Latest results tab

Displays the results for the latest tightenings.

Search Results tab

Use the Search button to search for results between specific dates.

Pinned tab for investigation

A tightening result can temporarily be stored into the Pinned tab. This is useful for detailed analysis of a tightening, and prevents the tightening result to be dropped from the window as new results are received.

Live results tab

A controller sends tightening results to ToolsTalk 2 as soon as the task is completed, and the result is added to the top of the Live results. A limited number of results can be stored. When the list is full, the oldest result is dropped from the list.

Imported tab

For viewing imported results.