Fieldbus parameters for DeviceNet
The table below only lists specific parameters for DeviceNet. For the general parameters, see Fieldbus Parameters General.
Field  | Description  | Default value  | 
|---|---|---|
Fieldbus node address  | 
  | 
  | 
Baud rate  | Speed of the communication link. Select speed from the drop-down menu. 125 kbps; 250 kbps; 500 kbps, Automatic.  | Automatic  | 
Connection mode  | Select the type of communication between the fieldbus master (PLC) and the subordinate controller. Select from a drop-down menu: 
  | 
  | 
To controller  | Total receive Process Data Frame. The frame size is a combination of all the virtual station receive frames. The size is expressed in number of bytes.  | |
From controller  | Total transmit Process Data Frame. The frame size is a combination of all the virtual station transmit frames. The size is expressed in number of bytes.  |