Installing the ToolsTalk Server Application
Before you begin with the ToolsTalk 2 server installation, make sure all the requirements are met as described in section Before Installing or Upgrading.
Before installing the Server Application, make sure that Atlas Copco Data Communication (ACDC) is installed and running (only for versions of ToolsTalk 2 from 2.13 onwards). Please see the ACDC Installation Manual.
Place the executable file ToolsTalkServer<xxx>.exe in a desired folder on your computer. The <xxx> represents the version of the file.
Double-click on the executable file.
If an error occurs during installation, a step is unclear, or a parameter name or value is unclear, look for more information in the Troubleshooting section.
Screen | Parameters |
---|---|
Welcome to the InstallShield Wizard | Select Next. |
License Agreement | Shown if it is a new client installation. Accept the license agreement. Select Next. |
Destination Folder | Shown if it is a new client installation. A default folder is provided for the program installation. This folder destination may be changed if needed. The folder destination must not be changed during a ToolsTalk 2 upgrade. Select Next. |
Controller Backup Folder (Valid only from v2.11) | Shown if it is a new client installation. A default folder is provided for the controller backup. This folder destination may be changed if needed. The folder destination must not be changed during a ToolsTalk 2 upgrade. Select Next. |
Database Server Determines how the ToolsTalk 2 server application connects to the SQL database. | Select the database server from the drop-down menu (recommendation is to use local), or browse to another server. Select authentication method by selecting one of the radio buttons (recommendation is to use Windows). If the server authentication is used, enter the Login ID and password for a system administrator on the server, or the account used when the SQL server was created. Create a database catalog for the ToolsTalk 2 application (recommendation is to use the default name ToolsTalkEventStore). The database catalog must not be changed during a ToolsTalk 2 upgrade. Select the Test DB Connection button to verify that the ToolsTalk 2 application connects with the SQL database. Select Next. |
Web Application Settings Determines how the user or client connects to the ToolsTalk 2 server application. | Select authentication method by selecting one of the radio buttons:
Set the hub port value, default is set to 4551. The setting must be the same on the server and in the controller configuration. Set the WebApi port value, default is set to 9101. The setting must be the same on the server and client installation. If the computer name of the server cannot be reached through a URL, Select the Convert ServiceURL to IP Address box. Select Next. |
Web Application Settings Determines how the user or client connects to the Atlas Copco Data Communication (ACDC) server application. | ACDC Server Settings:
Port Configuration:
Select Next. |
Ready to install the program | Select Install. |
InstallShield Wizard completed | Select Finish. |
If the SQL database server is installed on the same machine as the ToolsTalk 2 server application, select (local) in the Database server window.
If No security is used, any user in the domain can change a configuration parameter without identification.
If Windows accounts are used, changes made to configuration parameters are saved together with timestamp and identified user account.
For a simple installation, where all modules (SQL database, server application and client application) are installed on the same computer, the No security option may be used. This is a normal setup for a service engineering laptop computer.