Installing the ToolsTalk Server Application

Before you begin with the ToolsTalk 2 server installation, make sure all the requirements are met as described in section Before Installing or Upgrading.

Before installing the Server Application, make sure that Atlas Copco Data Communication (ACDC) is installed and running (only for versions of ToolsTalk 2 from 2.13 onwards). Please see the ACDC Installation Manual.

  1. Place the executable file ToolsTalkServer<xxx>.exe in a desired folder on your computer. The <xxx> represents the version of the file.

  2. Double-click on the executable file.

If an error occurs during installation, a step is unclear, or a parameter name or value is unclear, look for more information in the Troubleshooting section.

Screen

Parameters

Welcome to the InstallShield Wizard

Select Next.

License Agreement

Shown if it is a new client installation.

Accept the license agreement.

Select Next.

Destination Folder

Shown if it is a new client installation.

A default folder is provided for the program installation. This folder destination may be changed if needed.

The folder destination must not be changed during a ToolsTalk 2 upgrade.

Select Next.

Controller Backup Folder

(Valid only from v2.11)

Shown if it is a new client installation.

A default folder is provided for the controller backup. This folder destination may be changed if needed.

The folder destination must not be changed during a ToolsTalk 2 upgrade.

Select Next.

Database Server

Determines how the ToolsTalk 2 server application connects to the SQL database.

Select the database server from the drop-down menu (recommendation is to use local), or browse to another server.

Select authentication method by selecting one of the radio buttons (recommendation is to use Windows).

If the server authentication is used, enter the Login ID and password for a system administrator on the server, or the account used when the SQL server was created.

Create a database catalog for the ToolsTalk 2 application (recommendation is to use the default name ToolsTalkEventStore).

The database catalog must not be changed during a ToolsTalk 2 upgrade.

Select the Test DB Connection button to verify that the ToolsTalk 2 application connects with the SQL database.

Select Next.

Web Application Settings

Determines how the user or client connects to the ToolsTalk 2 server application.

Select authentication method by selecting one of the radio buttons:

  • No Security:

  • Use Windows accounts: If Windows accounts are used, the Active Directory Admin Group needs to be entered.

Set the hub port value, default is set to 4551.

The setting must be the same on the server and in the controller configuration.

Set the WebApi port value, default is set to 9101.

The setting must be the same on the server and client installation.

If the computer name of the server cannot be reached through a URL, Select the Convert ServiceURL to IP Address box.

Select Next.

Web Application Settings

Determines how the user or client connects to the Atlas Copco Data Communication (ACDC) server application.

ACDC Server Settings:

  • Server Address: Set the server address

Port Configuration:

  • Web API: Set the port, default is set to 7110

  • SignalR: Set the port, default is set to 8110

Select Next.

Ready to install the program

Select Install.

InstallShield Wizard completed

Select Finish.

If the SQL database server is installed on the same machine as the ToolsTalk 2 server application, select (local) in the Database server window.

If No security is used, any user in the domain can change a configuration parameter without identification.

If Windows accounts are used, changes made to configuration parameters are saved together with timestamp and identified user account.

For a simple installation, where all modules (SQL database, server application and client application) are installed on the same computer, the No security option may be used. This is a normal setup for a service engineering laptop computer.