Enabling and Disabling the Tightening Settings
The General Virtual Station configuration contains a tightening section, which is used to set parameters for Disable tightening and Disable loosening.
- Select a controller in the Plant structure  . .
- Go to the Configurations tab  in the menu bar. in the menu bar.- The workspace area displays the available Configurations. 
- Double-click on an existing General Virtual Station to configure, or select Add to create a new one to configure. 
- Make the relevant selections in the Tightening Settings parameters, according to the information in the tables below. 
| Parameter Value | Description | 
|---|---|
| Off | A disabled tool will remain disabled regardless of the loosening status. | 
| On OK | A disabled tool will be unlocked after an OK loosening has been performed. | 
| Always | A disabled tool will be unlocked as soon as a loosening has been performed, regardless of the loosening status. | 
| Disable loosening | Description | 
|---|---|
| Off | Disable loosening is Off. An operator can always loosen a screw. | 
| On OK tightening | Disable loosening for an OK tightening. An operator cannot loosen a screw that was terminated with tightening OK. | 
| On NOK tightening | Disable loosening for an NOK tightening. An operator cannot loosen a screw that was terminated with tightening NOK. | 
| Always | Disable loosening is always ON. An operator can never loosen a screw. | 
| Disable tightening | Description | 
|---|---|
| Off | Disable tightening is Off. An operator can always tighten a screw. | 
| On OK tightening | Disable tightening after an OK tightening. An operator cannot tighten another screw if the current tightening terminated with OK. | 
| On NOK tightening | Disable tightening after a NOK tightening. An operator cannot tighten another screw if the current tightening terminated with NOK. | 
| After every tightening | Disable tightening is activated after every tightening. An operator cannot tighten another screw until the current tightening is terminated. | 
Tool lock behavior
Tool lock behavior is set to Off by default. This behavior can be overridden to allow the tool to be unlocked by the operator by performing a loosening.
Allowing a disabled tool to unlock after loosening
- In the configuration used by the tool (set in the Virtual Station the tool is connected to), set the Unlock tool on loosening to On OK or Always.  - In order to enable the setting above, three conditions need to be met: - 1. The Disable loosening parameter cannot be set to Off or Always. - 2. The Disable loosening value cannot be set to the same value as the Disable tightening. - 3. The tightening program used must have loosening enabled. 
When the tool is locked for either tightening or loosening due to a disable state, it can be unlocked by any of the following input signals:
- Master_Unlock 
- Unlock_Tool_On_Disable 
This input signal can be sent to the controller either from an accessory, from a programable tool accessory, or from the Fieldbus unit.