Running a Loosening Sync Mode
A loosening sync mode can be run in following possible ways.

All the conditions to start a tightening must be fulfilled (example: no emergency stop, enable signal is set and so on) in order for all the above cases to work correctly.
Running a Loosening Sync Mode Using the Input Select Loosening
- Select a tightening sync mode with an associated loosening sync mode. - This can be done by adding the I/O signal Select Input, Id 10020 in the To controller area in the Fieldbus sub-tab under Fieldbus and SoftPLC  or this can also be done by selecting a task in the Task under the Virtual Station tab or this can also be done by selecting a task in the Task under the Virtual Station tab . .
 
- Select loosening using the I/O signal Select loosening, Id 10029 in the To controller area in the Fieldbus sub-tab under Fieldbus and SoftPLC  . .
- Start the loosening using any of the two signals: - Start drive (continuos), Id 10028 
- Start drive (pulse), Id 10113 
 
Running a Loosening Sync Mode Using Input Start Loosening
- Select a tightening sync mode with an associated loosening sync mode - This can be done by adding the I/O signal Select Input, Id 10020 in the To controller area in the Fieldbus sub-tab under Fieldbus and SoftPLC  or this can also be done by selecting a task in the Task under the Virtual Station tab or this can also be done by selecting a task in the Task under the Virtual Station tab . .
 
- Start the loosening using any of these two signals: - Start loosening (continuous), Id 10011 
- Loosening pulse start (pulse), Id 10072