Cleaning and Replacing the Bit Complete
Preparation
The Screw Feeding Front Part must be brought to the “Bit Change” mode. This is done by turning the rotary switch of the Screw Feeding Unit to the "Bit Change" position.
Remove the Feeding Head by pulling the Quick-Change Coupling backwards.
Removing the Bit Complete
Pull the Bit Quick-Change Coupling forwards.

The Bit Complete will pop out as soon the Bit Quick-Change Coupling is pulled forwards.

Cleaning and checking the Bit Complete
Clean the Bit Complete and remove any residuals.
Check the Bit Complete for wear and tear. In case of high wear or any defect, the corresponding part must be exchanged.
Mounting the Bit Complete
If no wear or defect can be detected, the clean Bit Complete can be reinstalled.
Insert the Bit Complete into the Sleeve with a slight twist until the toothing engages. The Bit Quick-Change Coupling jumps back automatically.