Start-up Progress Indications
Only valid for tools equipped with EHMI.
When starting the tool, the EHMI will indicate if a software update is in progress by displaying the following messages:
Check for software update
Updating <module> App/Boot
Starting controller
A module is a subsystem or component which is part of the IxB tool, and updated through the IxB Software.
Module (as shown on the display) | Description |
---|---|
MRT | Main board |
MCB | Power module |
FTS | Front transducer |
EHMI | Extended HMI |
BHMI | Basic HMI |
RMHI | Round HMI |
If an error occurs during the software update, the following message will be displayed:
Software update failed (error Id)
The error Id corresponds to error messages, as follows:
Id | Error Message | Description | Suggested Action |
---|---|---|---|
0 | None | - | - |
1 | Module board info not valid | Module produced with incorrect data | Replace module |
2 | Module device information not valid | Module produced with incorrect data | Replace module |
3 | Module file corrupt | File system is corrupt | Replace IAM |
4 | Module firmware not compatible with hardware | Software not compatible with hardware | Update to later release |
5 | Module firmware file not found | File system is corrupt | Replace IAM |
6 | Error when reading module firmware file | File system is corrupt | Replace IAM |
7 | Communication timeout when trying to update module | Damage on the connector/cable or the module | Replace IAM |
8 | Error when receiving data from module | Damage on the connector/cable or the module | Service the tool |
9 | Unexpected reply from module | Damage on the connector/cable or the module | Service the tool |
10 | Module unreachable | Damage on the connector/cable or the module | Service the tool |
11 | Error when transmitting data to module | Damage on the connector/cable or the module | Service the tool |
12 | System on backup battery | System is running on backup battery | Restart tool - do not remove battery or power adapter until update is complete |