Error message | Description | Required step category | Reporting step monitors | Reporting step restrictions | Reporting program monitors | Reporting program restrictions |
---|---|---|---|---|---|---|
Drive error | Internal drive error or battery removed during tightening | |||||
Rehit | Attempt to tighten an already tightened bolt. | Rehit | ||||
Soft start torque below min | Soft start torque below minimum level. | SoftStart | Peak Torque | Torque in Angle Window | ||
Soft start torque above max | Soft start torque exceeded maximum level. | SoftStart | Peak Torque | Maximum Torque | Maximum Torque Limit | |
Rundown torque above max | Rundown torque exceeded maximum level. | Rundown | Peak Torque | Maximum Torque | Maximum Torque Limit | |
Rundown angle above max | Rundown angle exceeded maximum level. | Rundown | Angle | Maximum Angle | ||
Rundown exceeding max time limit | Rundown time exceeded maximum limit. | Rundown | Time | Maximum Time | ||
Rundown below min time limit | Rundown time below minimum limit | Rundown | Time | |||
Rundown torque below min | Rundown torque below minimum level. | Rundown | Peak Torque | Torque in Angle Window | ||
Rundown angle below min | Rundown angle below minimum level | Rundown | Angle | |||
Final step torque above max | Final step torque exceeded maximum level. | Final | Peak Torque | Maximum Torque | Torque | Maximum Torque Limit |
Final step angle above max | Final step angle exceeded maximum level. | Final | Angle | Maximum Angle | Angle | |
Final step torque below min | Final step torque below minimum level. | Final | Peak Torque | Torque in Angle Window | Torque | |
Final step angle below min | Final step angle below minimum level. | Final | Angle | Angle | ||
Tightening timeout | Tightening time limit exceeded. | Maximum Time Limit | ||||
Trigger lost | Tool trigger was released before target was reached. | |||||
Slip off | Socket has slipped off the nut. | Rescinding Torque | ||||
Post view torque below min | Post view torque below minimum level. | Post View Torque Low | ||||
Post view torque above max | Post view torque exceeded maximum level. | Post View Torque High | ||||
Post view torque interval not reached | Post view torque interval not reached. | Post View Torque Low | ||||
Torque compensation interval not reached | Torque compensation interval angle before rundown end not reached | Prevailing Torque | ||||
Current monitoring error | Torque vs current deviation exceeds maximum level. | Torque vs Current Deviation | ||||
Soft start angle above max | Soft start angle exceeded maximum level. | SoftStart | Angle | Maximum Angle | ||
Soft start angle below min | Soft start angle below minimum level | SoftStart | Angle | |||
First step angle high | First step angle exceeded maximum level | First | Angle | Maximum Angle | ||
First step angle low | First step angle below minimum level | First | Angle | |||
First step torque high | First step torque exceeded maximum level | First | Peak Torque | Maximum Torque | Maximum Torque Limit | |
First step torque below min | First step torque below minimum level | First | Peak Torque | Torque in Angle Window | ||
First step exceeded max time limit | First step time exceeded maximum level | First | Time | Maximum Time | ||
First step below min time limit | First step time below minimum level | First | Time | |||
Final step exceeded max time limit | Final step time exceeded maximum level | Final | Time | Maximum Time | ||
Final step below min time limit | Final step time below minimum level | Final | Time | |||
Soft start exceeded max time limit | Soft start time exceeded maximum level | SoftStart | Time | Maximum Time | ||
Current at shut off exceeds max limit | Measured shutoff current exceeding max limit | Shut off current | ||||
Current at shut off below min limit | Measured shutoff current below min limit | Shut off current | ||||
Step exceeded max time | Step exceeded maximum step time | Time | ||||
Stopped | Stopped externally before target was reached |