NOK Results List

Error message

Description

Required step category

Reporting step monitors

Reporting step restrictions

Reporting program monitors

Reporting program restrictions

Drive error

Internal drive error or battery removed during tightening

Rehit

Attempt to tighten an already tightened bolt.

Rehit

Soft start torque below min

Soft start torque below minimum level.

SoftStart

Peak Torque
Post Thread Cut
Peak Torque Shut Off Torque
Torque in Angle Window

Torque in Angle Window

Soft start torque above max

Soft start torque exceeded maximum level.

SoftStart

Peak Torque
Post Thread Cut Peak Torque
Shut Off Torque
Torque in Angle Window

Maximum Torque
Torque in Angle Window

Maximum Torque Limit

Rundown torque above max

Rundown torque exceeded maximum level.

Rundown

Peak Torque
Prevailing Torque
Post Thread Cut Peak Torque
Shut Off Torque
Torque in Angle Window

Maximum Torque
Torque in Angle Window

Maximum Torque Limit

Rundown angle above max

Rundown angle exceeded maximum level.

Rundown

Angle
Post Thread Cut Angle

Maximum Angle

Rundown exceeding max time limit

Rundown time exceeded maximum limit.

Rundown

Time

Maximum Time

Rundown below min time limit

Rundown time below minimum limit

Rundown

Time

Rundown torque below min

Rundown torque below minimum level.

Rundown

Peak Torque
Prevailing Torque
Post Thread Cut Peak Torque
Shut Off Torque
Torque in Angle Window

Torque in Angle Window

Rundown angle below min

Rundown angle below minimum level

Rundown

Angle
Post Thread Cut Angle

Final step torque above max

Final step torque exceeded maximum level.

Final

Peak Torque
Post Thread Cut Peak Torque
Shut Off Torque
Torque in Angle Window

Maximum Torque
Torque in Angle Window

Torque

Maximum Torque Limit

Final step angle above max

Final step angle exceeded maximum level.

Final

Angle
Post Thread Cut Angle

Maximum Angle

Angle

Final step torque below min

Final step torque below minimum level.

Final

Peak Torque
Post Thread Cut Peak Torque
Shut Off Torque
Torque in Angle Window

Torque in Angle Window

Torque

Final step angle below min

Final step angle below minimum level.

Final

Angle
Post Thread Cut Angle

Angle

Tightening timeout

Tightening time limit exceeded.

Maximum Time Limit

Trigger lost

Tool trigger was released before target was reached.

Slip off

Socket has slipped off the nut.

Rescinding Torque

Post view torque below min

Post view torque below minimum level.

Post View Torque Low

Post view torque above max

Post view torque exceeded maximum level.

Post View Torque High

Post view torque interval not reached

Post view torque interval not reached.

Post View Torque Low
Post View Torque High

Torque compensation interval not reached

Torque compensation interval angle before rundown end not reached

Prevailing Torque

Current monitoring error

Torque vs current deviation exceeds maximum level.

Torque vs Current Deviation

Soft start angle above max

Soft start angle exceeded maximum level.

SoftStart

Angle
Post Thread Cut Angle

Maximum Angle

Soft start angle below min

Soft start angle below minimum level

SoftStart

Angle
Post Thread Cut Angle

First step angle high

First step angle exceeded maximum level

First

Angle
Post Thread Cut Angle

Maximum Angle

First step angle low

First step angle below minimum level

First

Angle
Post Thread Cut Angle

First step torque high

First step torque exceeded maximum level

First

Peak Torque
Post Thread Cut Peak Torque
Shut Off Torque
Torque in Angle Window

Maximum Torque
Torque in Angle Window

Maximum Torque Limit

First step torque below min

First step torque below minimum level

First

Peak Torque
Post Thread Cut Peak Torque
Shut Off Torque
Torque in Angle Window

Torque in Angle Window

First step exceeded max time limit

First step time exceeded maximum level

First

Time

Maximum Time

First step below min time limit

First step time below minimum level

First

Time

Final step exceeded max time limit

Final step time exceeded maximum level

Final

Time

Maximum Time

Final step below min time limit

Final step time below minimum level

Final

Time

Soft start exceeded max time limit

Soft start time exceeded maximum level

SoftStart

Time

Maximum Time

Current at shut off exceeds max limit

Measured shutoff current exceeding max limit

Shut off current

Current at shut off below min limit

Measured shutoff current below min limit

Shut off current

Step exceeded max time

Step exceeded maximum step time

Time

Stopped

Stopped externally before target was reached