General Virtual Station
Go to Configurations in the home menu and select General Virtual Station in the left pane.
Give the configuration a name and select Edit.
In the Result filter for reporting field, set the switch to On for those parameters that are to be included in the results. By default, all parameters are set to On.
The following parameters can be set in the Result filter for reporting field:
Loosening
Batch increment
Batch decrement
Reset batch
Bypass tightening program
Abort sequence
Abort not started sequence
Reset batch sequence
In the Tightening Settings, configure when to disable loosening and when to disable tightening after a tightening.
Parameter
Description
Unlock tool on loosening
Off, On OK, Always
Disable loosening
Off, On OK tightening, On NOK tightening, Always
Disable tightening
Off, On OK tightening, On NOK tightening, After every tightening