General Settings

Item

Description

Inactivity timeout

On: In order to save battery time there is an option to automatically turn off the tool after a certain time of inactivity.

Off: The tool will not be turned off due to inactivity.

Inactivity timeout

Time in minutes. Enter a value between 1-1440 minutes.

Front LED

On: The front LED white light turns on when the tool trigger is pressed. On supported tools, the front LED result indicator (green and red light) will turn on when the tool trigger is released to indicate a result. To configure the result indication, see Tool LEDs.

Off: The front LED does not turn on when the tool trigger is pressed or released.

Duration after trigger released

Sets how long the front LED white light stays lit after the tool trigger is released (in seconds).

The configuration does not affect the duration for the result indication (green or red light). To configure the duration of the result indication, see Tool LEDs.

Tightening program selection

On: LED ring provides visualization of currently selected tightening program in a sequence.

Off: Function deactivated.

Enable display buttons

On: All RHMI buttons are enabled. Default setting.

Off: All RHMI buttons are disabled, with the exception of result and event view.