Function Button
The function button on the tool can be configured to control up to six available input signals. The button’s three possible condition states are combined with the two possible states of the direction switch.
The function button is not available for ICB tools.
Go to Configurations in the home menu and select Tool Configurations > Edit.
Select 1. Function Button > Edit.
Set the parameters as applicable:
Function Button States
Direction Switch State
Pressed
CW
Single push
CW
Double push
CW
Pressed
CCW
Single push
CCW
Double push
CCW
Each of the six input signal combinations can be assigned one of the following items:
Item
Abort sequence
Acknowledge events
Activate tool scanner
Batch decrement
Batch increment
Bypass tightening program
Master unlock
Reset batch
Reset batch sequence
Reset too many NOK
Select next identifier number
Select previous identifier number
Unlock tool on complete
Unlock tool on disable
Set the Detection Interval parameters:
Parameter
Description
Default Value
Push detection interval
For single push: the maximum push time (in milliseconds) between the button being pressed and the button being released.
300 ms
Next push interval
For double push: the maximum time (in milliseconds) between the button being released after the first push, and the button being pressed again.
300 ms