Function Button

The function button on the tool can be configured to control up to six available input signals. The button’s three possible condition states are combined with the two possible states of the direction switch.

The function button is not available for ICB tools.

Configure the function button:
  1. Go to Configurations in the home menu and select Tool Configurations > Edit.

  2. Select 1. Function Button > Edit.

  3. Set the parameters as applicable:

    Function Button States

    Direction Switch State

    Pressed

    CW

    Single push

    CW

    Double push

    CW

    Pressed

    CCW

    Single push

    CCW

    Double push

    CCW

    Each of the six input signal combinations can be assigned one of the following items:

    Item

    Abort sequence

    Acknowledge events

    Activate tool scanner

    Batch decrement

    Batch increment

    Bypass tightening program

    Master unlock

    Reset batch

    Reset batch sequence

    Reset too many NOK

    Select next identifier number

    Select previous identifier number

    Unlock tool on complete

    Unlock tool on disable

  4. Set the Detection Interval parameters:

    Parameter

    Description

    Default Value

    Push detection interval

    For single push: the maximum push time (in milliseconds) between the button being pressed and the button being released.

    300 ms

    Next push interval

    For double push: the maximum time (in milliseconds) between the button being released after the first push, and the button being pressed again.

    300 ms