Testing in the Test Environment
In Configuration mode, on the Test Environment page, select the Workpiece ID of the workpiece to be tested in the dropdown menu.
To test all the bolt positions in the workpiece, select the TEST ALL button.
Alternatively, to test one bolt position in the workpiece, select the TEST button to the right of the bolt position ID in the table.
Place the tool socket on one bolt.
Select TRIGGER or press and release the tool trigger.
Use the movements that are required for the specific sensor and move the tool slowly and repeatedly around the bolt.

Make sure to cover the area that is relevant from a operating point of view while testing the tightening position.
The testing process starts.
The Status, Detect and Conflict results will show in the table for the bolt that is being tested.
When finished select TRIGGER or press and release the tool trigger.

The TRIGGER and RESET buttons will be enabled after the testing process has started and there will be a STOP button.
Select the TRIGGER button if the tool that is used does not have a trigger to start.
Select the RESET button to redo the testing.
Select the STOP button to stop the testing
Repeat steps 3-6 for each bolt. Make sure to do the testing in the correct order.
In the case there is a conflict it can be necessary to change the configuration or the teaching.