Preventive Maintenance Level 1
Maintenance level 1
Carry out maintenance after 6.000.000 pulses, when POWER FOCUS 6000 is indicating “Pulse unit oil level low” or once a year, whichever comes first.
For maximum tool performance follow below instructions and use recommended service tools and service kits from Atlas Copco. Always use tightening torque and lubrications as recommended by Atlas Copco.
Tool Handle
Make a visual inspection for any damage.
Inspect the yoke and suspension points.
Inspect the ball bearing in the Pulse unit casing and the surface of the Anvil.
Electric Motor
Listen to any unexpected noise.
Pulse Unit
Change the oil accordingly, see Oil Filling and Changing Instruction for Pulse Unit.
Make sure that the pulsing frequency is within limits, see Tool Condition Test.