Operating

As tightening torque increase the reaction force build up equally. Make sure that the tool is in correct working order and that the controller is correctly programmed to avoid unexpected behaviour from the tool, which may result in operator injury.

ETV/ETD: Check that the tool is in the correct running direction by turning the reverse ring,

  • Clockwise = Tool forward.

  • Anti clockwise = Tool reverse

ETP: Check that the tool is in the correct running direction by pushing the revers switch.

The soft-start function facilitates entering the screw head and thread.

The duration of the soft start is adjustable, see the manual for the POWER FOCUS/ drive unit.

The tool is equipped with four LED´s for specific tasks:

  • Connection LED: Indicates connection to Power Focus

  • Battery LED: Indicates battery status (flashing light for low and fixed light for empty battery)

  • Batch LED: Indicated Batch done

  • Alarm LED: A failure/event is detected