Product Data
Operating torque measuring range | from 10% to 100% of the smartHEAD nominal |
Maximum torque accuracy error (related to the value read by the STRwrench controller) | ± 0.1% |
Maximum torque linearity error (related to the value read by the STRwrench controller) | ± 0.015% |
Torque measurement accuracy (smartHEAD 15 Nm) | 0.5% readout ±1 digit (from 20% to 100% of nominal torque) |
Torque measurement accuracy (smartHEAD 80-1000 Nm) | 0.5% readout ±1 digit (from 10% to 100% of nominal torque) |
Overload capacity | 120% of smartHEAD nominal |
Temperature stability of torque measurement | 0.1% of nominal / 10°C |
Maximum angular speed | 150 °/s |
Angle measurement accuracy | ±1° over 360° without torque preload ±1° over 360° with torque preload |
Weight | 930 g |