Error Codes

LED
Indications

3 red flashes followed by 2 yellow flashes

Clutch sensor error. The tool does not start or stops correctly.

The signal given by the clutch sensor is out of tolerances. Do a check of the sensor and the magnets for the sensor. Make sure that the flex is connected correctly to the electronic board. If the fault still appears, contact customer service.

3 red flashes followed by 3 yellow flashes

The temperature is over the maximum limit of 70°C. The tool does not start or stops correctly.

The temperature measured with the electronic board is higher than 70°C. Wait for the tool to cool down. When the temperature is lower than 70°C it is possible to operate the tool again. Decrease the tool rate. If the temperature is lower than 70°C and the fault still appears, contact customer service

3 red flashes followed by 4 yellow flashes

Overheated tool. Too high current over too long time. The tool does not start or stops correctly.

The power requested is too big. If the fault still appears, contact customer service.

3 red flashes followed by 5 yellow flashes

Battery voltage fault. The tool does not start or stops correctly.

The battery voltage is not correct for the tool. Make sure that the correct battery is used. If the battery used is correct and the fault still appears, contact customer service.

3 red flashes followed by 6 yellow flashes

Overcurrent on the power circuit. The hardware limit is reached. The tool does not start or stops correctly.

If the fault still appears, the power stage is faulty, contact customer service

3 red flashes followed by 7 yellow flashes

Motor stall. The motor is blocked or the sensors feedback do not fit with the tool drive request.

Replace the motor. If after replacing the motor the fault still appears, contact customer service.