SPC (prod)
Below are the items of the SPC (prod) inspection result details card:
Inspection: name of the inspection.
Result date: date of the inspection result.
Status: completed.
Results status: NOK.
X/R Chart
X chart: chart of the average values. The last point is the average of the last subgroup. The previous points are the average values of the subgroups done before.
In the graphs, the lines indicate the upper and lower control limits (orange lines) if the measurement type is set to Average.
Click the chart to open a full screen graph.
R chart: chart of the range (maximum measured values - minimum measured values).
The last point is the range of the last execution. The previous points are the range values of the execution done before.
In the graphs, the lines indicate the upper and lower control limits (orange lines) if the measurement type is set to Range.
Click the chart to open a full screen graph.
Serial number: serial number of the tool.
Measurement of: Torque/Angle.
Measurement type: Average/Range.
SPC rule name: name of the SPC rule set in ToolsNet.
SPC rule failed: name of the SPC rule failed, below the available options:
Group outside of control limits: one or more groups are outside the upper control limit (UCL) or lower control limit (LCL).
Groups increasing or decreasing: 7 or more consecutive increasing or decreasing groups.
Group above or below average: 7 or more consecutive groups above or below average
Group size: number of results used for a sample set in ToolsNet.
High limit: high limit set in ToolsNet.
Target value: target value set in ToolsNet
Low limit: low limit set in ToolsNet
Upper control limit: upper control limit set in ToolsNet
Lower control limit: low control limit set in ToolsNet