Advanced parameters for Joint check inspections

Strategy: residual torque/angle

  • Cycle start: the cycle start is the starting point of the test.

    It must be higher than the transducer Minimum Load and equal/lower than the final angle monitoring torque.

    The default value is 0 N·m.

  • Ratchet time (*): type the value of the ratchet time.

  • Change screw (*): type the value of the change screw.

  • Final angle monitoring torque (*): type the value of the final angle monitoring torque.

  • Residual angle threshold (*): type the value of the residual angle threshold.

  • Breakaway angle threshold (*): type the value of the breakaway angle threshold.

  • Torque correction coefficient (*): type the value of the torque correction coefficient.

  • Angle correction (*): type the value of the angle correction.

Strategy: residual torque/peak

  • Cycle start: type the value of the cycle start.

    It must be higher than the transducer Minimum Load and equal/lower than the final angle monitoring torque.

    The default value is 0 N·m.

  • Ratchet time (*): type the value of the ratchet time.

  • Change screw (*): type the value of the change screw.

  • Final angle monitoring torque: type the value of the final angle monitoring torque.

  • Angle target: type the value of the target angle.

  • Torque correction coefficient (*): type the value of the torque correction coefficient.

  • Angle correction (*): type the value of the angle correction.

Strategy: Loose and tightening

The Loose and Tightening strategy is available only with STa 6000.

  • Cycle start: type the value of the cycle start.

    It must be higher than the transducer Minimum Load

    The default value is 0 N·m.

  • Change screw (*): type the value of the change screw.

  • Angle target: type the value of the target angle.

  • Torque correction coefficient (*): type the value of the torque correction coefficient.

  • Angle correction (*): type the value of the angle correction.