Editing a Tightening Program
On the Manager main menu, select Setup Tightening Programs.
Select a tightening program from the list.
Configure the tightening program.
Select TEST and perform a tightening with the tool. Test results are displayed in the Test result section. Inspect the results and check the joint with a calibrated torque wrench. If needed, change the Residual Torque Correlation Factor (RTCF). Repeat step 4 until the required result is obtained.
For more information about working with the Residual Torque Correlation Factor (RTCF), refer to Power Focus Configuration Guide.
Select SAVE to save changes.
To exit edit mode without applying any changes, select CANCEL. Never use the back button on the web browser to exit edit mode.