Setting the Tool in Standalone Mode

The tool is in Standalone mode when delivered. If the tool has been used in another mode after that, perform this procedure to set it back in Standalone mode.

Connecting the Web Interface to the Tool

  1. Make sure that the battery is not attached to the tool. Press and hold the Function button that is situated above the Tool trigger.

  2. Continue to press the Function button and attach the battery. The tightening direction LED will light up.

  3. When the tightening direction LED shuts off, release the Function button.

  4. When the tightening direction LED lights up again, press and hold the Function button.

  5. When the tightening direction LED shuts off, release the Function button. The tool is now in Standalone Mode and all LEDs are flashing. When all other LEDs stop flashing, the blue LED indicator for radio connection should continue flashing.

  6. Make sure that the blue LED indicator for radio connection on the tool is flashing.

  7. Use any browser device and set the network to the tool network (TBP_serial number). The blue LED indicator for radio connection on the tool is lit up in blue.

    The default password is 87654321.

  8. Open the web browser on the browsing device and enter the IP address of the tool (192.168.2.1).

    JavaScript has to be allowed on the browser device.

  9. The home page is displayed. Log in as Manager or Operator.

    The default password for Manager and Operator is password.