Advanced Section Configuration
Configure the Workflow for a Conditional Segment
In the Setup mode, on the Tools page, in the Tool tab, select the Edit button.
Select the Advanced section and select the CONFIGURE... button next to the Conditional segments text.
A Configure Workflow pop-up window opens.
Select or clear the External segment selection checkbox.
If the External segment selection is selected it activates listening to tc_selector_socket_info and disables the setting of segments from the workpiece itself.
Enter the Socket prefix.
The socket prefix adds a name to the conditional segment. If the field is empty, "Socket" is used for the name.
Select OK.
Configure the Workflow for Release Lock
By editing the Release Lock workflow it is possible for ILG to use one of the 8 Generic I/O signals instead of the regular Open Protocol messages MID0042/0043 disable/enable tool signals.
In the Setup mode, on the Tools page, in the Tool tab, select the Edit button.
Select the Advanced section and select the CONFIGURE... button next to the Release Lock text.
A Configure Workflow pop-up window opens.
Enter the I/O generic signal in the IO field.
Select or clear the Both checkbox.
If the Both checkbox is selected both MID0042/MID0043 and the Generic I/O will be triggered when ILG enables/disables the tool.
Select OK.
Configure the Workflow for a Standard Tool
In the Setup mode, on the Tools page, in the Tool tab, select the Edit button.
Select the Advanced section and select the CONFIGURE... button next to the Standard Tool text.
A Configure Workflow pop-up window opens.
Select or clear the checkbox for Bypass Positioning ID.
Positioning ID is only available when the Connection Type is ASDK or ASDK remote.
The selected checkbox for Bypass Positioning ID will result in ILG not using Positioning ID. If the preference is to use the full functionality of ASDK or ASDK remote, the user should not select this option.
In the Parameter set selection dropdown menu, select an option.
The Always option will always send a Pset.
The When different option will send a Pset when it is not already selected.
The Never option will never send a Pset.
In the Wait on parameter set dropdown menu, select an option.
The option No confirmation does not wait for a Pset.
The option Any Pset selected accepts any selected Pset without a specific ID.
The option Requested Pset selected requires a Pset with a specific ID that matchet the ID for the configured position in ILG.
Select OK.