I/O Expander and Stacklight Signals

Output signals

Signal

Signal Type

Value Type

Size Min [bit]

Size Max [bit]

Meaning

Batch Completed - 30

Event

Boolean

1

1

Batch Completed is an output signal which is triggered when the batch is complete. The batch result status (OK or NOK) has no effect on the Batch Completed signal.

Batch Completed NOK - 37

Event

Boolean

1

1

Batch finished with status NOK.

Batch Completed OK - 36

Event

Boolean

1

1

Batch finished with status OK.

Batch Running - 32

State

Boolean

1

1

Indicates that a batch in a batch sequence is running.

Batch Sequence Completed NOK - 46

Event

Boolean

1

1

Batch sequence finished with status NOK.

Batch Sequence Completed OK - 45

Event

Boolean

1

1

Batch sequence finished with status OK.

Batch Sequence Done - 48

Event

Boolean

1

1

Indicates when a sequence is completed, both in case Batch Sequence Completed OK and Batch Sequence Completed NOK.

Batch Sequence Running - 47

State

Boolean

1

1

Indicates if the Batch Sequence is running or not.

High Angle - 10

Event

Boolean

1

1

Angle result is higher than maximum angle limit.

High Torque - 7

Event

Boolean

1

1

Torque result is higher than maximum torque limit.

Identifier Received - 100

Event

Boolean

1

1

Identifier received by the system.

Low Angle - 9

Event

Boolean

1

1

Angle result is lower than minimum angle limit.

Low Torque - 6

Event

Boolean

1

1

Torque result is lower than minimum torque limit.

Max Consecutive NOK Reached - 35

Event

Boolean

1

1

Max coherent NOK tightening counter is reached.

Open Protocol Disconnected - 95

State

Boolean

1

1

If Open Protocol is set to off in the Virtual Station, "Open Protocol Disconnected" signal is set to False. If Open Protocol is turned on in the Virtual Station the "Open Protocol Disconnected" signal is set to True. When at least one client (several Open Protocol clients can connect to the same Virtual Station) is connected the "Open Protocol Disconnected" signal is set to False

Sequence Aborted - 160

Event

Boolean

1

1

Sequence canceled.

Tightening is Locked - 27

State

Boolean

1

1

The tightening is disabled; it is not possible to make any tightening.

Tightening NOK - 4

Event

Boolean

1

1

At least one result of the tightening is outside the specified limits.

Tightening OK - 3

Event

Boolean

1

1

The result of the tightening is within the specified limits.

Tool Battery Low - 90

State

Boolean

1

1

Tool battery level below a certain threshold.

Tool Disabled - 158

State

Boolean

1

1

Tool Disabled is an output signal which is activated when the tool is externally disabled.

Tool Enabled - 159

State

Boolean

1

1

Tool Enabled is an output signal which is activated when the tool is not externally disabled.

Tool Running - 23

State

Boolean

1

1

Indicates that the tool is rotating (clockwise [CW] or counter-clockwise [CCW]).

Input signals

Signal

Signal Type

Value Type

Size Min [bit]

Size Max [bit]

Description

Abort sequence - 10012

Event

Boolean

1

1

When a Batch sequence abort request is received, the Batch sequence functionality terminates the batch sequence only after getting the ongoing tightening result.

Batch Decrement - 10002

Event

Boolean

1

1

Incrementally decreases the batch counter by one.

Batch Increment - 10001

Event

Boolean

1

1

Incrementally increases the batch counter by one.

Bypass Tightening Program - 10008

Event

Boolean

1

1

Skips the next tightening program in the running batch sequence.

Reset Batch - 10003

Event

Boolean

1

1

Resets the batch counter to 0. No batch OK (nxOK). If batch OK is activated, it will be deactivated.

Reset Batch Sequence - 10053

Event

Boolean

1

1

Resets the Batch Sequence.

Input/Output signals

Signal

Signal Type

Value Type

Size Min [bit]

Size Max [bit]

Description

Disable Open Protocol Commands - 10060

State

Boolean

1

1

Disables the possibility to send commands over Open Protocol to the Virtual Station.