Tool configuration
On the home view, select Configurations and then select Tool Configuration on the left pane.
On the Configuration window:
Select Filter by tool type and select tool type.
Select Edit to configure the tool settings.
Configuring Multiple transducers
Only available for QST tools.
Depending on the tool type and the number of transducers, it is possible to set how the torque and angle transducers are used in a tightening. The transducers can be configured to be controlling or monitoring.
Parameter | Description |
|---|---|
Controlling torque transducer | Set the torque transducer to use for tightening. Available settings:
|
Controlling angle transducer | Set the angle transducer to use for tightening. Available settings:
|
Select Details to open a sub-menu with more settings.
Parameter | Description |
|---|---|
Report monitoring torque values | If set, a Final Torque value will be reported from both the controlling and the monitoring transducer, including an evaluation of the status for both (OK/High/Low). |
Redundancy error reporting torque | Redundancy error is reported if the Final Torque measured on the controlling transducer differ from the value measured on the monitoring transducer. |
Lock the tool on redundancy error | Lock the tool if a redundancy error is detected. |
Parameter | Description |
|---|---|
Require dual torque | If set, the connected tool must have dual torque transducers (that are not disabled) to be able to run a tightening. |
Monitoring torque in trace | If set, the values from the monitoring torque transducer are included in the trace. |
Parameter | Description |
|---|---|
Enable double torque restriction | If set, the double torque transducer restriction is active. |
Maximum torque difference | The limit for the double torque difference restriction. |
Parameter | Description |
|---|---|
Report monitoring angle values | If set, a Final Angle value will be reported from both the controlling and the monitoring transducer, including evaluation of the status for both (OK/High/Low). |
Redundancy error reporting angle | Redundancy error is reported if the Final Angle measured on the controlling transducer differ from the value measured on the monitoring transducer. |
Lock the tool on redundancy error | Lock the tool if a redundancy error is detected. |
Parameter | Description |
|---|---|
Require dual angle | If set, the connected tool must have dual angle transducers (that are not disabled) to be able to run a tightening. |
Monitoring angle in trace | If set, the values from the monitoring angle transducer is included in the trace. |
Parameter | Description |
|---|---|
Enable double angle restriction | If set, the double angle transducer restriction is active. |
Maximum angle difference | The limit for the double angle difference restriction. |
Configuring Start condition on the Tool
Select Start source and choose an item in the list.
Trigger only
Press the tool trigger to start the tightening.
Push only
Push the tool against the joint to start the tightening.
Trigger OR Push
Press the tool trigger or push the tool against the joint to start the tightening.
Trigger AND Push
Press the tool trigger and push the tool against the joint to start the tightening.
Safety trigger
Two triggers (as with trigger and push) activated within 500 ms from each other to start the tightening.
Digital input
Have a signal using digital input to trigger the start of the tightening.
Trigger AND Digital input
Press the tool trigger and use a signal through digital input to start the tightening.
Select Apply or Undo.