Method 2 (whitout an ACTA and Transducer):

This method is not as fast and accurate as using method 1. Fill the pulse unit with oil in accordance with the following instructions:

  1. Position the pulse unit in a vice. Remove the oil plug positioned on either the front or the back of the pulse unit. Fill the pulse unit to 100% full. Assemble the oil plug.

  2. Assemble the tool and run in reverse for 3-5 seconds.

  3. Position the pulse unit in a vice. Remove the oil plug. Wait for all air bubbles to dissapear (approximatley 15 minutes) and the temperature to drop down to 20 degrees.

  4. Fill the pulse unit to 100% full.

  5. Reduce the oil in the pulse unit with a specified volume according to table using a 1 ml syringe. Assemble the oil plug.

    Oil volume to be

    reduced from 100%

    Approx. oil volume

    in pulse-unit

    0.50 ± 0.05 ml

    5 ml

  6. Check torque and shut off function, for procedure see Testing/Measuring.

    • If everything is in order the amount of oil is right.

    • If everything is not in order repeat from step one.