Method 1 (when using an ACTA and a Transducer):
This method is the fastest and will also give an optimized tool performance and result in the longest filling intervals. Fill the pulse unit with oil in accordance with the following instructions:
Position the pulse unit in a vice. Remove the oil plug positioned on either the front or the back of the pulse unit. Add a small amount of oil to the pulse unit.
Assemble the tool and measure the pulse frequency, for more details on measuring the pulse frequency see Static measurement with fixed transducer.
If the pulse unit frequency is in the specified range the amount of oil is correct.
If the pulse unit frequency is to low reduce some oil and measure the pulse frequency again.
If the pulse frequency is to high add some oil and measure the pulse frequency again.
Model
Free speed (r.p.m)
Pulse frequency (Hz)
Max Torque (minimum) (Nm)
EP 8 PTX SR10
5700
20 - 23
62