Test conditions

Temperature pulse unit: approx. 20° C.

Air pressure: 6,3 bar (90psi) dynamic

Hose size: 8 mm Hose length: 3 m

The tool should achieve the following values after maintenance:

Model

Free speed (r.p.m)

Pulse frequency (Hz)

Min. Torque (Nm)

EP 8 PTX SR10

5700

20 - 23

62

Correct pulse frequency indicates that the air motor and the pulse unit are in good condition. If the pulse pulse frequency is to high - fill oil. If the pulse frequency is to low - reduce oil.